The DPM-400-LP-FI features the loop-powered, dual-line feet & inches display.
Please specify choice of output(s) in your Quote Request.
No Options Installed SKU 348-0089
2 Relays SKU 348-0090
4-20 mA SKU 348-0091
2 Relays & 4-20 mA Output SKU 348-0092
| Input | 4-20 mA |
|---|---|
| Power | 4-20 mA loop |
| Display | Dual-line LCD with backlight. Both lines 14-segment alphanumeric. Top: 0.7" (17.8 mm), Bottom: 0.4" (10.2 mm). Display may be programmed to turn red and flash a user-defined message on alarm condition. |
| Front Panel | NEMA 4X, IP65; NEMA 4X enclosures available |
| Backlight | Powered by 4-20 mA loop. Intensity varies with signal level |
| Display Update Rate | Ambient > -10°C: 1 update/second; Ambient = -20 C: 1 update/2 seconds; From -20°C to -40°C the update rate slows down 1 second for every 2°C (e.g. at -24°C, 1 update/4 seconds). |
| Non-Volatile Memory | All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost. |
| Environmental | Operating temperature range: -40 to 75°C |
| Relative humidity | 0 to 90% non-condensing. Printed circuit boards are conformally coated. |
| Programming Method | Front panel & Free PC-based USB programming software |